Connectors, Interconnects
3-88179-0
ActiveTE Connectivity Raychem Cable Protection
CONN HOUSING RCP 10 POS 2.54MM CRIMP ST CABLE MOUNT BLACK PACKAGE
Deep-Dive with AI
Search across all available documentation for this part.

Connectors, Interconnects
3-88179-0
ActiveTE Connectivity Raychem Cable Protection
CONN HOUSING RCP 10 POS 2.54MM CRIMP ST CABLE MOUNT BLACK PACKAGE
Deep-Dive with AI
Technical Specifications
Parameters and characteristics for this part
| Specification | 3-88179-0 |
|---|---|
| Connector Type | Housing for Female Contacts |
| Current Rating (Amps) | 1.5 A |
| Features | Positions Stamped |
| FFC, FCB Thickness | 0.015 mm |
| Flat Flex Type | FFC, Discrete Wire |
| Housing Color | Black |
| Housing Material | Polyamide (PA), Nylon, Glass Filled |
| Insulation Diameter [Max] [diameter] | 0.069 " |
| Insulation Diameter [Max] [diameter] | 1.75 mm |
| Insulation Diameter [Min] [diameter] | 0.045 in |
| Insulation Diameter [Min] [diameter] | 1.14 mm |
| Locking Feature | Detent Lock |
| Material Flammability Rating | UL94 V-0 |
| Note | Contacts Not Included |
| Number of Positions | 10 |
| Number of Rows | 2 |
| Operating Temperature [Max] | 105 ░C |
| Operating Temperature [Min] | -65 ░C |
| Pitch [x] | 2.54 mm |
| Pitch [x] | 0.1 in |
| Voltage Rating | 300 VDC |
| Wire Gauge [Max] | 32 AWG |
| Wire Gauge [Min] | 22 AWG |
88179 Series
| Part | Voltage Rating | Number of Positions | Number of Rows | Material Flammability Rating | Locking Feature | Housing Color | Operating Temperature [Min] | Operating Temperature [Max] | Housing Material | Flat Flex Type | Connector Type | Features | Insulation Diameter [Max] [diameter] | Insulation Diameter [Max] [diameter] | Insulation Diameter [Min] [diameter] | Insulation Diameter [Min] [diameter] | Current Rating (Amps) | Wire Gauge [Max] | Wire Gauge [Min] | Pitch [x] | Pitch [x] | Note | FFC, FCB Thickness |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() TE Connectivity Raychem Cable Protection | 300 VDC | 40 | 2 | UL94 V-0 | Detent Lock | Black | -65 ░C | 105 ░C | Polyamide (PA) Nylon Glass Filled | FFC Discrete Wire | Housing for Female Contacts | Positions Stamped | 0.069 " | 1.75 mm | 0.045 in | 1.14 mm | 1.5 A | 32 AWG | 22 AWG | 2.54 mm | 0.1 in | Contacts Not Included | 0.015 mm |
![]() TE Connectivity Raychem Cable Protection | 300 VDC | 40 | 2 | UL94 V-0 | Detent Lock | Black | -65 ░C | 105 ░C | Polyamide (PA) Nylon Glass Filled | FFC Discrete Wire | Housing for Female Contacts | Positions Stamped | 0.069 " | 1.75 mm | 0.045 in | 1.14 mm | 1.5 A | 32 AWG | 22 AWG | 2.54 mm | 0.1 in | Contacts Not Included | 0.015 mm |
![]() TE Connectivity Raychem Cable Protection | 300 VDC | 10 | 2 | UL94 V-0 | Detent Lock | Black | -65 ░C | 105 ░C | Polyamide (PA) Nylon Glass Filled | FFC Discrete Wire | Housing for Female Contacts | Positions Stamped | 0.069 " | 1.75 mm | 0.045 in | 1.14 mm | 1.5 A | 32 AWG | 22 AWG | 2.54 mm | 0.1 in | Contacts Not Included | 0.015 mm |
TE Connectivity Raychem Cable Protection | 300 VDC | 38 | 2 | UL94 V-0 | Detent Lock | Black | -65 ░C | 105 ░C | Polyamide (PA) Nylon Glass Filled | FFC Discrete Wire | Housing for Female Contacts | Positions Stamped | 0.069 " | 1.75 mm | 0.045 in | 1.14 mm | 1.5 A | 32 AWG | 22 AWG | 2.54 mm | 0.1 in | Contacts Not Included | 0.015 mm |
![]() TE Connectivity Raychem Cable Protection | 300 VDC | 24 | 2 | UL94 V-0 | Detent Lock | Black | -65 ░C | 105 ░C | Polyamide (PA) Nylon Glass Filled | FFC Discrete Wire | Housing for Female Contacts | Positions Stamped | 0.069 " | 1.75 mm | 0.045 in | 1.14 mm | 1.5 A | 32 AWG | 22 AWG | 2.54 mm | 0.1 in | Contacts Not Included | 0.015 mm |
![]() TE Connectivity Raychem Cable Protection | 300 VDC | 20 | 2 | UL94 V-0 | Detent Lock | Black | -65 ░C | 105 ░C | Polyamide (PA) Nylon Glass Filled | FFC Discrete Wire | Housing for Female Contacts | Positions Stamped | 0.069 " | 1.75 mm | 0.045 in | 1.14 mm | 1.5 A | 32 AWG | 22 AWG | 2.54 mm | 0.1 in | Contacts Not Included | 0.015 mm |
![]() TE Connectivity Raychem Cable Protection | 300 VDC | 22 positions | 2 | UL94 V-0 | Detent Lock | Black | -65 ░C | 105 ░C | Polyamide (PA) Nylon Glass Filled | FFC Discrete Wire | Housing for Female Contacts | Positions Stamped | 0.069 " | 1.75 mm | 0.045 in | 1.14 mm | 1.5 A | 32 AWG | 22 AWG | 2.54 mm | 0.1 in | Contacts Not Included | 0.015 mm |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Description
General part information
88179 Series
Housing, Wire-to-Board, 10 Position, 2.54 mm [.1 in] Centerline, 2 Row, Socket, Package, Normal, Straight, Black, FFC Connectors
Documents
Technical documentation and resources