Zenode.ai Logo
DM1200UB-10V

DM1200UB-10V

Active
Danisense A/S

CURRENT TRANSDUCER 1200A

DM1200UB-10V

DM1200UB-10V

Active
Danisense A/S

CURRENT TRANSDUCER 1200A

Description

General part information

DM1200UB-10V

Current Sensor 1200A 1 Channel Flux Gate, Closed Loop Bidirectional Module, Single Pass Through

Technical Specifications

Parameters and characteristics for this part

SpecificationDM1200UB-10V
Current - Sensing1200 A
Current - Supply (Max)141 mA
For MeasuringAC, DC
Linearity Tolerance0.0015 %
Maximum Frequency300 kHz
Minimum FrequencyDC
Mounting TypeChassis Mount
Number of Channels1
Operating Temperature (Max)65 °C
Operating Temperature (Min)-40 °C
OutputVoltage, Ratiometric
Package / CaseModule, Single Pass Through
PolarizationBidirectional
Response Time1 µs
Sensor TypeClosed Loop, Flux Gate
Voltage - Supply (Maximum)15.75 V
Voltage - Supply (Minimum)-14.25 V

Pricing

Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly

Sign in to see pricing

Create a free account to access distributor pricing data.

CAD

3D models and CAD resources for this part

Documents

Technical documentation and resources

No documents available