Description
General part information
EVAL3KW50VPSUTOBO1
This design introduces a complete Infineon’s system solution for a 3 kW power supply unit (PSU) targeting the newly released OCP V3 rectifier specifications for servers and data centers. The PSU comprises a front-end AC-DC bridgeless totem pole converter followed by a back-end DC-DC isolated half-bridge LLC converter. The front-end totem pole converter provides power factor correction (PFC) and total harmonic distortion (THD). The LLC converter provides safety isolation and a tightly regulated output voltage. The measured peak efficiency of the complete PSU at 230 VAC is 97.5%, not including the internal fan, and 97.4%, including the internal fan. The overall outer dimensions of the PSU are 73.5 mm x 520 mm x 40 mm, which yields a power density in the range of 32 W/inch³ (1.95 W/cm³). This system solution is available as Hardware Board or Reference Design.
Technical Specifications
Parameters and characteristics for this part
| Specification | EVAL3KW50VPSUTOBO1 |
|---|---|
| Board Type | Fully Populated |
| Contents | Board |
| Current - Output | 60 A |
| Isolated Output Count | 1 |
| Main Purpose | Primary and Secondary Side with PFC, AC/DC |
| Output Type | Isolated |
| Power - Output | 3 kW |
| Regulator Topology | Flyback |
| Supplied Contents | Board(s) |
| Total Output Count | 1 |
| Utilized IC / Part | ICE2QR2280G, XMC1404, XMC4200 |
| Voltage - Input (AC) Maximum | 275 V |
| Voltage - Input (AC) Minimum | 180 VAC |
| Voltage - Output | 50 V |