ENTUBE QE (250VAC 7VAC L-L)
ActiveVerivolt LLC
TRANSDUCER VOLTAGE DIVIDER
Deep-Dive with AI
Search across all available documentation for this part.
DocumentsDatasheet

ENTUBE QE (250VAC 7VAC L-L)
ActiveVerivolt LLC
TRANSDUCER VOLTAGE DIVIDER
Deep-Dive with AI
DocumentsDatasheet
Technical Specifications
Parameters and characteristics commom to parts in this series
| Specification | ENTUBE QE (250VAC 7VAC L-L) | ENTUBE QE Series | 
|---|---|---|
| Accuracy | 0.2 % | 0.2 % | 
| Input Range | - | 50 - 1500 V | 
| Input Range [Max] | 250 VAC | 250 - 1000 VAC | 
| Input Range [Min] | 0 VAC | -1000 - 0 VAC | 
| Mounting Type | DIN Rail | DIN Rail | 
| Operating Temperature [Max] | 70 °C | 70 °C | 
| Operating Temperature [Min] | -25 °C | -25 °C | 
| Output | - | 5 - 10 V | 
| Output [Max] | 7 VAC | 7 VAC | 
| Output [Min] | 0 VAC | 0 VAC | 
| Termination Style | RJ45, Spring Terminal | RJ45, Spring Terminal | 
| Type | Voltage Transducer | Voltage Transducer | 
ENTUBE QE Series
TRANSDUCER VOLTAGE DIVIDER
| Part | Termination Style | Type | Output | Accuracy | Operating Temperature [Max] | Operating Temperature [Min] | Mounting Type | Input Range | Input Range [Max] | Input Range [Min] | Output [Max] | Output [Min] | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Verivolt LLC ENTUBE QE (1500V 5V L-N) | RJ45, Spring Terminal  | Voltage Transducer  | 5 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 1500 V  | ||||
Verivolt LLC ENTUBE QE (1500V 5V L-L) | RJ45, Spring Terminal  | Voltage Transducer  | 5 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 1500 V  | ||||
Verivolt LLC ENTUBE QE (250VAC 7VAC L-L) | RJ45, Spring Terminal  | Voltage Transducer  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 250 VAC  | 0 VAC  | 7 VAC  | 0 VAC  | ||
Verivolt LLC ENTUBE QE (750V 5V L-L) | RJ45, Spring Terminal  | Voltage Transducer  | 5 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 750 V  | ||||
Verivolt LLC ENTUBE QE (500V 10V L-N) | RJ45, Spring Terminal  | Voltage Transducer  | 10 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 500 V  | -500 V  | |||
Verivolt LLC ENTUBE QE (300V 10V L-N) | RJ45, Spring Terminal  | Voltage Transducer  | 10 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 300 V  | ||||
Verivolt LLC ENTUBE QE (50V 5V L-N) | RJ45, Spring Terminal  | Voltage Transducer  | 5 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 50 V  | ||||
Verivolt LLC ENTUBE QE (500VAC 7VAC L-L) | RJ45, Spring Terminal  | Voltage Transducer  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 500 VAC  | 0 VAC  | 7 VAC  | 0 VAC  | ||
Verivolt LLC ENTUBE QE (750V 5V L-N) | RJ45, Spring Terminal  | Voltage Transducer  | 5 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 750 V  | ||||
Verivolt LLC ENTUBE QE (1000V 5V L-N) | RJ45, Spring Terminal  | Voltage Transducer  | 5 V  | 0.2 %  | 70 °C  | -25 °C  | DIN Rail  | 1000 V  | -1000 V  | 
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
| Distributor | Package | Quantity | $ | |
|---|---|---|---|---|
| Digikey | Box | 1 | $ 503.70 | |
Description
General part information
ENTUBE QE Series
Voltage Transducer 0 ~ 250VAC Input 0 ~ 7VAC Output DIN Rail
Documents