LFMWLT200-1303
ActiveEOS Power
AC/DC CONVERTER 24V 160W
Deep-Dive with AI
Search across all available documentation for this part.

LFMWLT200-1303
ActiveEOS Power
AC/DC CONVERTER 24V 160W
Deep-Dive with AI
Technical Specifications
Parameters and characteristics commom to parts in this series
Specification | LFMWLT200-1303 | MWLT200 Series |
---|---|---|
Applications | Medical | Medical |
Approval Agency | cUL, CE, UL, CB, NEMKO | cUL, CE, UL, CB, NEMKO |
Current - Output 1 | 6.67 A | 3.33 - 16.67 A |
Efficiency | 86 % | 86 % |
Features | Adjustable Output, Universal Input, Standby Output, Remote Sense, Remote On/Off, PFC, DC Input Capable | Adjustable Output, Universal Input, Standby Output, Remote Sense, Remote On/Off, PFC, DC Input Capable |
Minimum Load Required | False | False |
Mounting Type | Chassis Mount | Chassis Mount |
Number of Outputs | 1 | 1 |
Operating Temperature [Max] | 70 °C | 70 °C |
Operating Temperature [Min] | -20 °C | -20 °C |
Power (Watts) | 200 W, 160 W | 83 - 200 W |
Power (Watts) | - | 130 W |
Size / Dimension [x] | 5 in | 5 in |
Size / Dimension [x] | 127 mm | 127 mm |
Size / Dimension [y] | 3 " | 3 " |
Size / Dimension [y] | 76.2 mm | 76.2 mm |
Size / Dimension [z] | 38.1 mm | 38.1 mm |
Size / Dimension [z] | 1.5 " | 1.5 " |
Type | Enclosed | Enclosed |
Voltage - Input [Max] | 390 VDC, 264 VAC | 264 - 390 VDC |
Voltage - Input [Min] | 90 VAC, 120 VDC | 90 - 120 VAC |
Voltage - Isolation | 5.9 kV | 5.9 kV |
Voltage - Output 1 | 24 V | 5 - 48 V |
MWLT200 Series
AC/DC CONVERTER 48V 160W
Part | Minimum Load Required | Operating Temperature [Min] | Operating Temperature [Max] | Type | Number of Outputs | Voltage - Output 1 | Features | Voltage - Input [Min] | Voltage - Input [Max] | Voltage - Isolation | Efficiency | Approval Agency | Mounting Type | Applications | Current - Output 1 | Size / Dimension [x] | Size / Dimension [y] | Size / Dimension [x] | Size / Dimension [z] | Size / Dimension [y] | Size / Dimension [z] | Power (Watts) | Power (Watts) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
EOS Power LFMWLT200-1304 | -20 °C | 70 °C | Enclosed | 1 | 48 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 3.33 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1303 | -20 °C | 70 °C | Enclosed | 1 | 24 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 6.67 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1305 | -20 °C | 70 °C | Enclosed | 1 | 30 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 5.33 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1301 | -20 °C | 70 °C | Enclosed | 1 | 12 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 13.33 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1003 | -20 °C | 70 °C | Enclosed | 1 | 24 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 6.67 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1302 | -20 °C | 70 °C | Enclosed | 1 | 15 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 10.67 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1002 | -20 °C | 70 °C | Enclosed | 1 | 15 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 10.67 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1005 | -20 °C | 70 °C | Enclosed | 1 | 30 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 5.33 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1001 | -20 °C | 70 °C | Enclosed | 1 | 12 V | Adjustable Output, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 13.33 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W | ||
EOS Power LFMWLT200-1004 | -20 °C | 70 °C | Enclosed | 1 | 48 V | Adjustable Output, DC Input Capable, PFC, Remote On/Off, Remote Sense, Standby Output, Universal Input | 90 VAC, 120 VDC | 264 VAC, 390 VDC | 5.9 kV | 86 % | CB, CE, cUL, NEMKO, UL | Chassis Mount | Medical | 3.33 A | 5 in | 3 " | 127 mm | 38.1 mm | 76.2 mm | 1.5 " | 160 W, 200 W |
Pricing
Prices provided here are for design reference only. For realtime values and availability, please visit the distributors directly
Distributor | Package | Quantity | $ | |
---|---|---|---|---|
Digikey | Bulk | 42 | $ 98.66 |
Description
General part information
MWLT200 Series
Enclosed AC DC Converters 1 Output 24V 90 ~ 264 VAC, 120 ~ 390 VDC Input
Documents
Technical documentation and resources
No documents available